Kontakt z DI-BOX

flag_pl flag_ua flag_en flag_de

PLIKI COOKIES - Przebywając na naszych stronach wyrażają Pańtwo zgodę na używanie cookies, zgodnie z aktualnymi ustawieniami Państwa przeglądarki. Witryna wykorzystuje niektóre pliki 'cookies' ('ciasteczka') dla lepszego działania (m.in. analizy statystyk ruchu w witrynie).

ask for quotation

ELECTROMAGNETIC FLOW METER

Flow rate measurement


INTENDED USE

Electromagnetic flow meters are intended for liquid flow rate measurements in closed channels. The flow meters measure flow rate of conductive liquids, with and without impurities, aggressive or inert as well as conductive mixtures and pulps. Electrical conductivity of the medium for standard version shall exceed 5 mS/cm. The flow meters do not reduce pressure and do not have any mechanical parts. Electromagnetic flow meters measure volumetric flow of liquids with solid impurities.

 

Exemplary instalations of electromagnetic flow meters------------

Exemplary instalations of electromagnetic flow meters   Exemplary instalations of electromagnetic flow meters

Exemplary instalations of electromagnetic flow meters   Different instalations of electromagnetic flow meters

 

FLOW RANGES

Zakresy przepływów dla wybranych średnic

 

APPLICATION

a) Liquid flow rate

Electromagnetic flow meters in standard version measure liquid flow rate at 0.1 m/s to 10 m/s linear velocity.

b) Liquid conductivity

The liquid flowing through the flow meter sensor shall have an electrical conductivity > 5 mS/cm (special version: electrical conductivity > 0.35 mS/cm).

c) Full section flow

Flow meter sensor installation method shall provide flow in the full section of a line. The sensor is usually installed in the ascending line or the lower section of line elbow (water trap).

 

SENSOR INSTALLATION METHOD - pipelines

 

assembly of electromagnetic flow meter on a pipeline

 

GENERAL SPECIFICATIONS

a) Transmitter

  • Housing type: wall or board mounted

  • Supply: ~230 V, 50 Hz

  • Outputs: current 0/4...20mA, relay 2 x 2A/25V DC

  • Special version: RS-485 output, printer compatible (RS232C)

  • Verification for metering purposes - Central Office of Measures

  • Ambient temperature: -5...50°C

  • Protection rating: wall mounted unit: IP54, board mounted unit: IP40

b) Sensor

  • Sensor diameter: 3 mm to 2000 mm

  • Measuring range: 0...10 m/s

  • Measuring accuracy:

  • - 0.1...0.5 m/s – ±1% of the actual flow rate

  • - 0.5...10 m/s - ±0.5% of the actual flow rate

  • Ambient temperature: -30...60°C

  • Protection rating: IP65

  • Available connections: bolted, clamping, compression or flange

  • Max. pressure: do 4MPa

 

CONTENTS

The set includes:

  • Microprocessor trasmitter

  • Sensor

  • Cable, sensor to transmitter (standard length = 10 meters)

  • On request: verification certificate

Electromagnetic flow meter DI-BOX

Copyright 2002-2016 DI-BOX

Zobacz również:


Do pomiarów przepływu cieczy w kanałach grawitacyjnych w szczególności polecamy przepłwyomierz ultradźwiękowy FLOWBOX.